METSEPM82401 PowerLogic PM8000 meter intermediate metering MID certification
First file
Second file
Third file
The PowerLogic PM8000 series meters are compact, cost-effective multifunction power meters that will help you ensure reliability and efficiency of your power-critical facility. They reveal and provide understanding of complex power quality conditions enabling action to be taken to mitigate any issue. The PowerLogic PM8000 series meters have the versatility to perform nearly any job you need a meter to do, wherever you need it! The modular, flexible ION technology architecture enables a simple, building block approach for customizing each meter to any application. With patented Disturbance Direction Detection, revenue grade accuracy, multiple communication ports, onboard power quality analysis, web interface and a color graphical display. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). This version is also MID approved. The PowerLogic PM8000 series provides data quality confidence you can count on. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 50 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Wide control power range of 90-415 VAC / 110-415 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. Panel mounting (1/4 DIN) with integrated display.
Main Range PowerLogic product name PowerLogic PM8000 Product or component type Power meter Device short name PM8240 Market segment Buildings large building cost management: billing: sub feeder
Buildings small building network management: main incomer
Buildings medium building network management: main incomer
Buildings large building network management: main incomer
Buildings large building network management: sub feeder
Buildings multi-site network management: main incomer
Buildings multi-site network management: sub feeder
Data center network management: main incomer
Data center network management: sub feeder
Healthcare network management: main incomer
Healthcare network management: sub feeder
Industry network management: main incomer
Industry network management: sub feeder
Utility: sub feedermodel type Standard Complementary Power quality analysis Conforming to EN 50160: 2010 compliance report
conforming to IEEE 519: 2014 compliance report
conforming to IEC 61000-4-30: class S power quality measurement
up to the 63rd harmonic
harmonic distortion
waveform capture
voltage sag and swell detection
programmablity (logic and math functions)
conforming to IEC 62586 power quality monitoring
disturbance direction detection
rapid voltage changeDevice application WAGES metering
Power monitoringType of measurement Current
Voltage
Frequency
Active and reactive power total
Apparent power total
Power factor total
Active and reactive power per phase, rms
Apparent power per phase, rms
Power factor per phase, rmssupply voltage 90...415 V AC 45...65 Hz +/- 10 %
110...415 V DC +/- 10 %Network frequency 50 Hz
60 Hz[In] rated current 1 A
10 A
5 APoles description 3P + N
1P + N
3PPower consumption in VA 16 VA at 230 V AC Display type Colour TFT LCD Display resolution 320 x 240 pixels QVGA Sampling rate 256 samples/cycle Measurement current 50…10000 mA Analogue input type Voltage (impedance 5 MOhm)
Current (impedance 0.3 mOhm)Measurement voltage 57…400 V AC 42...69 Hz between phase and neutral
100…690 V AC 42...69 Hz between phasesFrequency measurement range 42…69 Hz Number of inputs 3 digital 30 V AC
3 digital 60 V DCMeasurement accuracy Current +/- 0.1 %
Voltage +/- 0.1 %
Active energy +/- 0.2 %Accuracy class Class 0.2S active energy conforming to IEC 62053-22
Class 0.2 active energy conforming to ANSI C12.20
Class 0.2 active power conforming to IEC 61557-12
Class 0.5S reactive energy conforming to IEC 62053-24
Class 0.5 power factor conforming to IEC 61557-12
Class 0.2 voltage conforming to IEC 61557-12
Class 0.2 current conforming to IEC 61557-12Number of outputs 1 pulse Information displayed Voltage
Current
Frequency
Power
Energy consumption
Harmonic distortionCommunication port protocol Modbus RTU at 115 kbauds - 2-wire
ION at 115 kbauds - 2-wire
DNP3
IEC 61850
Modbus TCP/IP
Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
RSTP 801.1d 2004Communication port support ETHERNET
Screw terminal block: RS485Data recording Time stamping
Sequence of event recording
GPS synchronisation
Min/max of instantaneous values
Event logs
Sag and swell logs
Harmonics logs
Trending/forecasting
Data logs
Alarm logs
Waveform logs
50 data recordersMemory capacity 512 MB Web services Customizable home page
File upload/download via FTP
File upload/download via SFTP
Web server
Alarm notification by e-mail
Viewing of captured waveform (FTP)
Viewing of captured waveform (web)
HTTPS serverCommunication service RSTP support
SMTP e-mail notification
NTP time synchronization
SNMP
PTP time synchronizationMounting mode Flush-mounted Mounting support Framework Installation category III Safety Construction III400…690 V conforming to IEC 61010-1:ed. 3
III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3Standards IEC 61557-12
IEC 62052-11
IEC 62053-22
IEC 62053-24
IEEE 1588
IEC 62586-2
IEC 61326-1Product certifications CE
CULus
N998
MIDWidth 96 mm Depth 77.5 mm Height 96 mm Net weight 581 g