LC1G400KUEN Contactor, high power, TeSys Giga, standard version, 3 pole/NO
TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 400A 250kW@440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
Specifications
Main Range TeSys Range of Product TeSys Giga Product or Component Type Contactor Device short name LC1G contactor application Power switching
Motor controlUtilisation category AC-1
AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8a
AC-8b
DC-1
DC-3
DC-5poles description 3P [Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC[Ie] rated operational current 550 A (at <104 °F (40 °C)) at <= 1000 V AC-1
400 A (at <140 °F (60 °C)) at <= 440 V AC-3[Uc] control circuit voltage 100...250 V AC 50/60 Hz
100...250 V DCControl circuit voltage limits Operational: 0.8 Uc Min...1.1 Uc Max (at <140 °F (60 °C))
Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))Complementary [Uimp] rated impulse withstand voltage 8 kV Overvoltage category III [Ith] conventional free air thermal current 550 A (at 104 °F (40 °C)) Rated breaking capacity 3480 A at 440 V [Icw] rated short-time withstand current 3.6 kA - 10 s
2.4 kA - 30 s
1.7 kA - 1 min
1.2 kA - 3 min
1.0 kA - 10 minAssociated fuse rating 500 A aM at <= 440 V for motor
315 A aM at <= 690 V for motor
630 A gG at <= 690 VAverage impedance 0.0001 Ohm [Ui] rated insulation voltage 1000 V Power dissipation per pole 30 W AC-1 - Ith 550 A
16 W AC-3 - Ith 400 ACompatibility code LC1G Pole contact composition 3 NO Auxiliary contact composition 1 NO + 1 NC Motor power kW 110 kW at 230 V AC 50/60 Hz (AC-3e)
200 kW at 400 V AC 50/60 Hz (AC-3e)
200 kW at 415 V AC 50/60 Hz (AC-3e)
250 kW at 440 V AC 50/60 Hz (AC-3e)
250 kW at 500 V AC 50/60 Hz (AC-3e)
315 kW at 690 V AC 50/60 Hz (AC-3e)
220 kW at 1000 V AC 50/60 Hz (AC-3e)
110 kW at 230 V AC 50/60 Hz (AC-3)
200 kW at 400 V AC 50/60 Hz (AC-3)
200 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
250 kW at 500 V AC 50/60 Hz (AC-3)
315 kW at 690 V AC 50/60 Hz (AC-3)
220 kW at 1000 V AC 50/60 Hz (AC-3)
110 kW at 230 V AC 50/60 Hz (AC-4)
200 kW at 400 V AC 50/60 Hz (AC-4)
200 kW at 415 V AC 50/60 Hz (AC-4)
220 kW at 440 V AC 50/60 Hz (AC-4)
250 kW at 500 V AC 50/60 Hz (AC-4)
315 kW at 690 V AC 50/60 Hz (AC-4)
220 kW at 1000 V AC 50/60 Hz (AC-4)Maximum Horse Power Rating 125 hp at 200/208 V 60 Hz
150 hp at 230/240 V 60 Hz
300 hp at 460/480 V 60 Hz
400 hp at 575/600 V 60 HzIrms rated making capacity 5090 A at 440 V Coil technology Built-in bidirectional peak limiting Safety reliability level B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1
B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1Mechanical durability 8 Mcycles inrush power in VA (50/60 Hz, AC) 750 VA inrush power in W (DC) 660 W hold-in power consumption in VA (50/60 Hz, AC) 15.5 VA hold-in power consumption in W (DC) 9.3 W Operating time 40...70 ms closing
15...50 ms openingMaximum operating rate 600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
150 cyc/h AC-4Connections - terminals Power circuit: bar 2 - busbar cross section: 32 x 10 mm
Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²)
Power circuit: bolted connection
Control circuit: push-in 1 0.0003…0.004 in² (0.2…2.5 mm²) - cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.0004…0.004 in² (0.25…2.5 mm²) - cable stiffness: flexible with cable end
Control circuit: push-in 2 0.0008…0.002 in² (0.5…1.0 mm²) with cable end
Control circuit: push-in 0.001…0.004 in² (0.75…2.5 mm²) - cable stiffness: solid stranded without cable end
Control circuit: push-in 0.001…0.004 in² (0.75…2.5 mm²) - cable stiffness: flexible with cable endConnection pitch 1.8 in (45 mm) Mounting Support Plate Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-1
UL 60335-2-40:Annex JJProduct Certifications CB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GLTightening torque 309.8 lbf.in (35 N.m) Height 8.9 in (225 mm) Width 5.5 in (140 mm) Depth 8.9 in (226 mm) Net Weight 16.5 lb(US) (7.5 kg)