The GV3 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV3PE controls motors with full load currents up to 65 amperes. The manual starter is three pole with horsepower ratings. The manual starter is operated by a rotary handle. The Class 10 ambient compensated thermal over current is adjustable from 48 ampere to 65 ampere. This device has EVERLINK terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Only 4 left in stock
  • Specifications

    Main
    Range TeSys Deca
    Product name TeSys GV3
    TeSys Deca
    Product or Component Type Motor circuit breaker
    Device short name GV3P
    Device Application Motor protection
    Trip unit technology Thermal-magnetic
    Complementary
    Poles description 3P
    Network type AC
    Utilisation category AC-3 IEC 60947-4-1
    Network frequency 50/60 Hz IEC 60947-4-1
    Fixing mode 35 mm symmetrical DIN rail clipped
    Panel screwed with 3 x M4 screws)
    Motor power kW 30 kW 400/415 V AC 50/60 Hz
    45 kW 500 V AC 50/60 Hz
    55 kW 690 V AC 50/60 Hz
    Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
    50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
    50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
    12 kA Icu 500 V AC 50/60 Hz IEC 60947-2
    6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
    [Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
    100 % 400/415 V AC 50/60 Hz IEC 60947-2
    100 % 440 V AC 50/60 Hz IEC 60947-2
    50 % 500 V AC 50/60 Hz IEC 60947-2
    50 % 690 V AC 50/60 Hz IEC 60947-2
    Control Type Rotary handle
    Line Rated Current 65 A
    Thermal protection adjustment range 48…65 A IEC 60947-4-1
    Magnetic tripping current 910 A
    [Ith] conventional free air thermal current 65 A IEC 60947-4-1
    [Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
    [Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
    [Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
    Phase failure sensitivity Yes IEC 60947-4-1
    Suitability for isolation Yes IEC 60947-1
    Power dissipation per pole 8 W
    Mechanical durability 50000 cycles
    Electrical durability 50000 cycles AC-3 415 V In
    Rated duty Continuous IEC 60947-4-1
    Tightening torque 44.25 lbf.in (5 N.m) screw clamp terminal
    Width 2.17 in (55 mm)
    Height 5.20 in (132 mm)
    Depth 5.35 in (136 mm)
    Net Weight 2.12 lb(US) (0.96 kg)
    color Dark grey
    Environment
    Standards EN/IEC 60947-2
    EN/IEC 60947-4-1
    UL 60947-4-1
    CSA C22.2 No 60947-4-1
    Product Certifications CCC
    UL
    CSA
    EAC
    ATEX
    LROS (Lloyds register of shipping)
    BV
    ABS
    DNV-GL
    UKCA
    IK degree of protection IK09 enclosure
    IP degree of protection IP20 IEC 60529
    Climatic withstand IACS E10
    Ambient Air Temperature for Storage -40…176 °F (-40…80 °C)
    Fire resistance 1760 °F (960 °C) IEC 60695-2-11
    Ambient air temperature for operation -4…140 °F (-20…60 °C)
    Mechanical robustness Shocks 15 Gn for 11 ms contactor open
    Shocks 30 Gn for 11 ms contactor closed
    Vibrations 4 Gn, 5...300 Hz
    Operating altitude 9842.52 ft (3000 m)