$379.00Price

TeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for 3-phase motor applications 0.25-0.37kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD05 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Only 5 left in stock
  • Specifications

    Main
    Range TeSys Deca
    Product name TeSys GV2
    Product or Component Type Motor circuit breaker
    Device short name GV2LE
    Device Application Motor protection
    Trip unit technology Magnetic
    Complementary
    Poles description 3P
    Network type AC
    Utilisation category Category A IEC 60947-2
    AC-3 IEC 60947-4-1
    AC-3e IEC 60947-4-1
    Network frequency 50/60 Hz IEC 60947-2
    Fixing mode 35 mm symmetrical DIN rail clipped
    Panel screwed with adaptor plate)
    Motor power kW 0.25 kW 400/415 V AC 50/60 Hz
    0.37 kW 400/415 V AC 50/60 Hz
    0.37 kW 500 V AC 50/60 Hz
    0.55 kW 690 V AC 50/60 Hz
    0.75 kW 690 V AC 50/60 Hz
    Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
    100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
    100 kA Icu 440 V AC 50/60 Hz IEC 60947-2
    100 kA Icu 500 V AC 50/60 Hz IEC 60947-2
    100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
    [Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
    100 % 400/415 V AC 50/60 Hz IEC 60947-2
    100 % 440 V AC 50/60 Hz IEC 60947-2
    100 % 500 V AC 50/60 Hz IEC 60947-2
    100 % 690 V AC 50/60 Hz IEC 60947-2
    Control Type Toggle
    Line Rated Current 1 A
    Magnetic tripping current 13 A
    [Ith] conventional free air thermal current 1 A IEC 60947-4-1
    [Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
    [Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
    [Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
    Suitability for isolation Yes IEC 60947-1 § 7-1-6
    Power dissipation per pole 1.8 W
    Mechanical durability 100000 cycles
    Electrical durability 100000 cycles AC-3 415 V In
    100000 cycles AC-3e 415 V In
    Rated duty Continuous IEC 60947-4-1
    Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
    Width 1.77 in (45 mm)
    Height 3.50 in (89 mm)
    Depth 3.09 in (78.5 mm)
    Net Weight 0.73 lb(US) (0.33 kg)
    color Dark grey
    Environment
    Standards EN/IEC 60947-2
    EN/IEC 60947-4-1
    UL 60947-4-1
    CSA C22.2 No 60947-4-1
    Product Certifications CCC
    UL
    CSA
    EAC
    LROS (Lloyds register of shipping)
    BV
    RINA
    DNV-GL
    UKCA
    IECEE CB Scheme
    IK degree of protection IK04
    IP degree of protection IP20 IEC 60529
    Climatic withstand IACS E10
    Ambient Air Temperature for Storage -40…176 °F (-40…80 °C)
    Fire resistance 1760 °F (960 °C) IEC 60695-2-11
    Ambient air temperature for operation -4…140 °F (-20…60 °C)
    Mechanical robustness Shocks 30 Gn for 11 ms
    Vibrations 5 Gn, 5...150 Hz
    Operating altitude 6561.68 ft (2000 m)