METSEPM2130, Power & Energy meter, up to the 31st harmonic, LED display, RS485
This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having 3 rows of bright red 4 digits 14.2 mm height LED display. The meter measures active energy as per accuracy class Class 0.5S complying to IEC 62053-22 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion and Individual harmonics up to 31st Harmonic order. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 80 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. It is having RS485 communication port over Modbus RTU protocol. The meter can be upgraded with optional add on IO modules for WAGES monitoring. These module comes with either two channels each of digital inputs and outputs or analog inputs and outputs. This version can be configured for 23 different types of alarms stored in 40 registers. Product dimensions are as follows: width 3.78 in (96 mm), depth 2.16 in (54 mm), height 3.78 in (96 mm) and product weight 10.58 oz (300 g).
Specifications
Main Range EasyLogic Product name EasyLogic PM2100 device short name PM2130 Product or Component Type Power meter Complementary Device Application Sub billing
Power monitoringPower quality analysis Total harmonic distortion
up to the 31st harmonicType of measurement Apparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy totalMetering type Peak demand currents
Active power P, P1, P2, P3
Demand power P, Q, S
Reactive power Q, Q1, Q2, Q3
Apparent power S, S1, S2, S3
Active, reactive, apparent energy (signed, four quadrant)
Voltage U, U21, U32, U13, V, V1, V2, V3
Current I, I1, I2, I3
Calculated neutral current
Unbalance current
Peak demand power PM, QM, SMAccuracy class Class 1 reactive energy IEC 62053-24
Class 0.5S active energy IEC 62053-22
Class 5 harmonic distorsion (I THD & U THD)Measurement accuracy Apparent power +/- 0.5 %
Active energy +/- 0.5 %
Reactive energy +/- 1 %
Active power +/- 0.5 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %Measurement current 5…6000 mA Measurement voltage 35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VTFrequency measurement range 45…65 Hz [Us] rated supply voltage 80...277 V AC 45...65 Hz +/- 10 %
100...277 V DC +/- 10 %Network Frequency 50 Hz
60 HzRide-through time 50 ms 120 V AC typical
50 ms 230 V AC typical
50 ms 125 V DC typicalLine Rated Current 1 A
5 AMaximum power consumption in VA 8 VA 277 V AC Maximum power consumption in W 3.3 W power lines (AC))
3.3 W 277 V power lines (DC))input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)Tamperproof of settings Protected by access code Display Type 7 segments LED Display colour Red Messages display capacity 3 fields of 4 characters Display digits 12 - 0.56 in (14.2 mm) Demand intervals Configurable from 1 to 60 min Information displayed Demand current past value)
Demand current present value)
Demand power past value)
Demand power present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %Control type 3 x button Local signalling Red LED output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED module operation and integrated communicationNumber of inputs 0 Number of Outputs 0 Communication port protocol Modbus RTU 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires 2500 V Communication port support Screw terminal block RS485 data recording Power logs
Time stamping
Energy consumption logs
Min/max for 8 parametersFunction Available Real time clock Sampling rate 64 samples/cycle Cybersecurity Enable/disable communication ports Communication Service Remote monitoring Product certifications CE IEC 61010-1
CULus UL 61010-1
CULus CSA C22.2 No 61010-1
RCM
EAC
C-tickMounting Mode Clip-on Mounting position Vertical Mounting support Framework Provided equipment 1 x Installation guide Measurement category Category III 480 V
Category II 480…600 VElectrical Insulation Class Class II
Double insulationFlame retardance V-0 conforming to UL 94 Connections - terminals Current transformer screw connection bottom) 6
Voltage inputs screw connection top) 4Material Polycarbonate Width 3.78 in (96 mm) Depth Total 3.00 in (76.09 mm)
Embedded 2.43 in (61.64 mm)Height 3.78 in (96 mm) Net Weight 10.58 oz (300 g) Compatibility code PM2130 Environment Service Life 7 year(s) IP degree of protection Front IP54 IEC 60529
Body IP30 IEC 60529Relative humidity 5…95 % 122 °F (50 °C) Pollution degree 2 Ambient air temperature for operation 14…140 °F (-10…60 °C) Ambient Air Temperature for Storage -13…158 °F (-25…70 °C) Operating altitude <= 6561.68 ft (2000 m) Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC Part 15 class AOvervoltage category III