METSEPM8213 Power quality meter, PowerLogic PM8000, transducer, 512 MB 256 s/c
The PowerLogic PM8000 series meters are compact, cost-effective multifunction power meters that will help you ensure reliability and efficiency of your power-critical facility. They reveal and provide understanding of complex power quality conditions enabling action to be taken to mitigate any issue. The PowerLogic PM8000 series meters have the versatility to perform nearly any job you need a meter to do, wherever you need it! The modular, flexible ION technology architecture enables a simple, building block approach for customizing each meter to any application. With patented Disturbance Direction Detection, revenue grade accuracy, multiple communication ports, onboard power quality analysis, web interface and a color graphical display. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). The PowerLogic PM8000 series provides data quality confidence you can count on. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 50 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Low voltage control power range of 24-60 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. DIN rail mounting transducer meter (no display).
Specifications
Main Range PowerLogic Product name PowerLogic PM8000 Device short name PM8213 Product or Component Type Power meter Complementary Power quality analysis EN 50160 2010 compliance report
IEEE 519 2014 compliance report
IEC 61000-4-30 class S power quality measurement
up to the 63rd harmonic
harmonic distortion
waveform capture
voltage sag and swell detection
programmablity (logic and math functions)
IEC 62586 power quality monitoring
disturbance direction detection
rapid voltage changeDevice Application WAGES metering
Power monitoringType of measurement Current
Voltage
Frequency
Active and reactive power total
Apparent power total
Power factor total
Active and reactive power per phase, rms
Apparent power per phase, rms
Power factor per phase, rmssupply voltage 20...60 V DC +/- 10 % Network Frequency 60 Hz
50 HzLine Rated Current 1 A
10 A
5 APoles description 3P
1P + N
3P + NPower Consumption in W 17 W display type Without Display Sampling rate 256 samples/cycle Measurement current 50…10000 mA Analogue input type Voltage (impedance 5 MOhm)
Current (impedance 0.3 mOhm)Measurement voltage 57…400 V AC 42...69 Hz between phase and neutral
100…690 V AC 42...69 Hz between phasesFrequency measurement range 42…69 Hz Number of inputs 3 digital 30 V AC
3 digital 60 V DCMeasurement accuracy Current +/- 0.1 %
Voltage +/- 0.1 %
Active energy +/- 0.2 %Accuracy class Class 0.2S active energy IEC 62053-22
Class 0.2 active energy ANSI C12.20
Class 0.2 active power IEC 61557-12
Class 0.5S reactive energy IEC 62053-24
Class 0.5 power factor IEC 61557-12
Class 0.2 voltage IEC 61557-12
Class 0.2 current IEC 61557-12Number of Outputs 1 pulse Information displayed Voltage
Current
Frequency
Power
Energy consumption
Harmonic distortionCommunication port protocol Modbus RTU 115 kbauds - 2-wire
ION 115 kbauds - 2-wire
DNP3
IEC 61850
Modbus TCP/IP
Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
RSTP 801.1d 2004Communication port support ETHERNET
Screw terminal block RS485Communication Network Type IPv6 (internet protocol) data recording Event logs
Min/max of instantaneous values
Time stamping
GPS synchronisation
Alarm logs
Data logs
Trending/forecasting
Sag and swell logs
Waveform logs
Sequence of event recording
Harmonics logs
50 data recordersmemory capacity 512 MB Web services Customizable home page
File upload/download via FTP
File upload/download via SFTP
Web server
Alarm notification by e-mail
Viewing of captured waveform (FTP)
Viewing of captured waveform (web)
HTTPS serverCommunication Service DHCP
SNMP
SMTP e-mail notification
RSTP support
NTP time synchronization
PTP time synchronizationCybersecurity Robust security logs
Syslog protocol support
Password protection
Port hardening
Enable/disable communication portsMounting Mode Clip-on Mounting support DIN rail installation category III Safety Construction III400…690 V conforming to IEC 61010-1:ed. 3
III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3Standards IEC 62053-24
IEC 62052-11
IEC 61557-12
IEC 62053-22
IEEE 1588
IEC 62586-2
IEC 61326-1Product certifications CE
CULus
N998Width 3.56 in (90.5 mm) Depth 3.57 in (90.8 mm) Height 3.56 in (90.5 mm) Net Weight 18.62 oz (528 g) Environment Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Immunity to impulse waves conforming to IEC 61000-4-12
Conducted and radiated emissions conforming to EN 55022
Conducted and radiated emissions conforming to EN 55011
Conducted and radiated emissions conforming to FCC part 15
Conducted and radiated emissions conforming to ICES-003
Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579
Surge withstand conforming to IEEE C37.90.1IP degree of protection IP30 conforming to IEC 60529 Relative humidity 5…95 % Ambient air temperature for operation -13…158 °F (-25…70 °C) Ambient Air Temperature for Storage -40…185 °F (-40…85 °C) Operating altitude 9842.52 ft (3000 m)